M302 p1. Make anothe mark on the filament right where it leaves the fitting. M302 p1

 
 Make anothe mark on the filament right where it leaves the fittingM302 p1 0

Now with Marilin 2. Ok I will try the. Here is my diagnostic file and my config. Extruding some filament with M302 P1 enabled (cold extrusion) with bowden out of hotend Extruding some filament with hotend at required temperature Printing a test print. @jens55 you are right dude I had missing to remplace one "S" argument by "H" in homez. This topic has been deleted. 4. The config changes were correct. Only users with topic management privileges can see it. In that case, you might use M302 S65 or similar to drop the MIN_TEMP. To test for this, with the power off swap the E0 connector on the Duet with another one e. 5beta2 regarding the 'M302 P1' cold extrusion command. extrusion temperature 160. M302: Allow cold extrudes Examples M302 M302 P1 This tells the printer to allow movement of the extruder motor, when the hotend is not at printing temperature. Put this as first line of your custom gcode. Re: How can I move E steppers? January 11, 2023 02:36AMM302 P1 ; disable cold extrusion checking And yes each extruder is a tool T0 G1 E20 ; move current extruder 20mm T1 G1 E20 T2 G1 E20 Edited 2 time(s). Our innovative life science, applied science, and clinical products are now found under the Applied Biosystems™, Invitrogen™, Gibco™, Ion Torrent™, and Molecular Probes™ brands. 1) into the DWC console. You will have to preheat the hotend first before moving E or you can try sending the M302 P1 Gcode via the terminal in pronterface to allow cold extrusion. Sending M302 P1 shows green as though it accepts the command, but the extrude & retract buttons are still grayed out. . com], E3D tool changer, Robotdigg SCARA printer, Crane Quad and OrmerodDisclosure: I design Duet electronics and work on RepRapFirmware, []. M302 works fine in a starting script or sent via console. g. M302 P0 ; disable cold extrusion M291 P"Filament autoload complete!" S0 T3 ; display message . To test for this, with the power off swap the E0 connector on the Duet with another one e. The extrusion amount of the first layer is extremely low, but the other layers are fine. g underneath: M122 === Diagnostics === RepRapFirmware for Duet 3 Mini 5+ version 3. If that's not the case, we need to change the direction of rotation. G-Codes¶. I have preheated the nozzle to 160 and also tried to issue a M302 P1 but that does not help either. Just need to find settings for Slice Engineering 300c thermistor, the temp reading slightly higher than actual measured with an TC thermometer. Large delta printer [miscsolutions. CryptoI did try a cold extrude M302 P1. g. Now all the other axis are moving as supposed but the extruder ones are not. M569 P0 S1 ; Reverse the X motor M563 P0 D0 H1 ; Define tool 1 G10 P0 S0 R0 ; Set tool 1 operating and standby temperatures M563 P1 D1 H2 ; Define tool 2 (un-comment this for dual nozzle machines) G10 P1 X19 S0 R0 ; Set tool 2 operating and standby temperatures (un-comment this for dual nozzle machines) M92 E447:447 ; Set. I just wondered if there was a way of "embedding" it in the config files so that it runs by default I'll set up a macro instead Thanks guysSo are you still getting phase errors, or is that resolved? @jfavre said in Extruder motor not working. Life Technologies was acquired by Thermo Fisher Scientific in January, 2014. Re-enable with. gco] Select SD file M23 filename. Re: Extrude without a Hotend May 04, 2017 11:25PM. e. W} F10000 ; grab filament for automatic feed while sensors. yello3d. It may have allowed the extruder to run on the 6HC but I'm thinking the DWC may have still been blocking the sending of any extrude or retraction presses while it looked only at the temperature before enabling the sowtware buttons. If you are using the web interface, go to the Gcode. @dc42 That doesn't seem to work. 1 Reply Last reply Reply Quote 0. G10 P1 X0 Y0 Z0 ; Set tool 1 axis offsets G10 P1 R0 S0 ; Set initial tool 1 active and standby temperatures to 0C M302 S120 R110 ; Allow extrusion starting from 120°C and retractions already from 110°C The retract and extrude control in extrusion control panel can't be active. Crypto@gloomyandy are these values incorrect?; Tools M563 P0 S"volcano" D0 H1 F0 ; define tool 0 G10 P0 X0 Y0 Z0 ; set tool 0 axis offsetsExtruder SKR2 not spinning. M302. I read up on the on "Connecting endstop switches - What might go wrong" and then I corrected the wiring and all is good with that. 0. M302 P1; Axis Limits M208 X-50 Y0 Z0 U0 S1 ; set axis minima M208 X210 Y220 U260 Z200 S0 ; set axis maxima ; Endstops M574 X1 S1 P"io0" ; configure switch-type (e. Unfortunately, the paper did not have anything about the exact settings. Sending M302 P1 shows green as though it accepts the command, but the extrude & retract buttons are still grayed out. So no need to use M302. M302 ; report current cold extrusion state M302 P0 ; enable cold extrusion checking M302 P1 ; disable cold extrusion checking M302 S0 ; always allow extrusion (disable checking) M302 S170 ; only allow extrusion above 170 M302 S170 P1 ; set min extrude temp to 170 but leave disabled. g ; set bed and extruder max temperatures; --- SECTION: FANS ( ) ---M106 P0 S0 I0 F4 H-1 L0. 3 E40 ; set drive mapping. is not colored in WebControl as in the example screenshots i saw. This topic has been deleted. All models of the M1 carbine family (including the M2 and M3 carbines) fired a . g and resume. Failure to extrude in RepRapFirmware is usually caused by either cold extrusion prevention (but you have sent M302 P1 to disable that), or not having the tool selected. Hello, I am building a clay printer and everything is working fine so far (with your help). I have a duex5 attached to a Duet Wifi with firmware 2. Extrusion Control in DWC unavailable, even after M302 P1. oracledude 5 Dec 2021, 21:47. . M570 S180 ; allow it 180 seconds before gving a heating warning and test hotends wont be tuned. Heating Bed manually by G-Code. This document describes the commands that Klipper supports. x) G92 A-1 B-1 ; Make Zrot & Tilt active G1 A0 B0 ; 3. Extrude a small amount to ensure that your extruder motor is on and holding. 2. 2. M302 P1 ; Allow Cold extrudes; Thermistors M305 P0 T100000 B3950 R2200 H30 L0 M305 P1 T100000 B3950 R2200 H30 L0 M305 P2 T100000 B3950 R2200 H30 L0. 1 active and standby temperatures to 0C G10 P1 X0 Y0 Z0 ; Set tool 1 axis offsets G10 P1 R0 S0 ; Set initial tool 1 active and standby temperatures to 0C M302 S120 R110 ; Allow extrusion starting from 120°C and retractions already from 110°C G10 P1 X0 Y0 Z0 ; Set tool 1 axis offsets G10 P1 R0 S0 ; Set initial tool 1 active and standby temperatures to 0C M302 S120 R110 ; Allow extrusion starting from 120°C and retractions already from 110°C $\begingroup$ That fix, sending M302 P1 (the P1 is important) and then M500 can be done in any program that can communicate directly with the printer. send T0), and enable cold extrusion with M302 P1. Duet Web Control makes it easy to upload, edit and create new macros. M302. -> no reaction at all - even after "M302 P1" What is working: Homing. 2 E1. When I try to run the extruder (for example G1 E1) I make sure to allow cold extrusion (M302 P1). is not colored in WebControl as in the example screenshots i saw. 499. the X motor. 455513e-8Ok if the motor is confirmed working, then at least cold extrusion should allow it to extruder as long as the tool is actually selected. 0C, min. 0C, min. GameStop Moderna Pfizer Johnson & Johnson AstraZeneca Walgreens Best Buy Novavax SpaceX Tesla. 5mm/sec echo "Done" M82 ; set extruder to abs modeBusiness, Economics, and Finance. gpIn[0]. M302 P1 ; disable cold extrusion checking And yes each extruder is a tool T0 G1 E20 ; move current extruder 20mm T1 G1 E20 T2 G1 E20 Edited 2 time(s). 0. wordpress. M302 P1 M584 E3:4;M563 P0 D3:4 ; Define tool 0 (no heaters assigned);M567 P0 E1:1;M584 E3:4;M302 P1 ;COLD EXTRUSION ON; Network M550 PXTP1 ; Set machine name M540 PBE:EF:DE:AD:FE:ED ; Set MAC address M552 P0. 0. The button movement range is about 0. trigger3. So when i home it, x and y go to 225 and z goes to 0. On the X and Y we are using iHSS57-36-10 closed loop. 7. After creating these and making all the connections we can move onto updating the firmware. @dc42 Having seen your post I also checked the frequency on a multimeter and indeed it shows 49. M117 Let's make some filament!;Turn on fan;M106. 3 (3. Equipped with a remote controller designed for enterprise users and the newly upgraded Pilot 2 flight app, to improve the efficiency of drone operations. +Z should move the bed down. Usage. At no point does the output of M591 D0 change, it always states no calibration data and never reports a sensor angle. M302 P0 disallows cold extrusion. The SMuFF is supposed to beep for 1 second. The home position is detected by the punch slide HP sensor (PS302). Set nozzle and bed temperature to something below 30°C so the hotend fan wont spin up. This topic has been deleted. I'm attempting to drive I was successful in driving a Maxon DC motor with encoder (pulled from a Stratasys Dimension 1200es BST) with a Duet 2 Wifi via a Geckodrive G320x Digital. Sending M302 P1 shows green as though it accepts the command, but the extrude & retract buttons are still grayed out. g. droftarts administrators @flyscha last edited by . If calibrating cold: Bowden: Disconnect the bowden tube from your extruder. M302 P1 disables the cold extrude safety. I have a setup similar to the ANET A8. I have waisted hours t. Orange - unload button is pressed (only when filament is present) Please note the filament sensing button used here is not a standard TACT switch. CryptoBusiness, Economics, and Finance. (You'll need to pull hard sometimes) Step 7 Printer: Anycubic Chiron, Firmware: Marlin 2. @o_lampe said in Error: Driver 5 does not support x1 microstepping: M584 X0 Y1 Z2 E5 ; set drive mapping M569 P5 S1 T25:25:25:25 ; physical drive 5 is external (DUE) M350 E1 ; no microsteps,. Many thanks! ;FLAVOR:Marlin ;TIME:40 ;Filament used: 0. 16 07:24. M302 P0. 5beta2 regarding the 'M302 P1' cold extrusion command. In order to move the extruder, do I need set the temperature control input for the extruder heater? I have setup multiple tools that share a heater and have dedicated extruder drives. 0 D9. Then reduce the distance, and stop just before the filament disappears into the hot end. 0 S1 ; Enable network and acquire dynamic address via DHCP M586 P0 S1 ; Enable HTTPM302 P1;M563 P0 D3:4 ; Define tool 0 (no heaters assigned);M567 P0 E1:1;M584 E3:4;M302 P1 ;COLD EXTRUSION ON; Network M550 PXTP1 ; Set machine name M540 PBE:EF:DE:AD:FE:ED ; Set MAC address M552 P0. Life Sciences. I thought I was having problems outputting STEP and DIR to the G320x, but actually it was a current issue in 3. If you unload it first, you can safely send M302 P1 to permit the extruder to work without heating up the hotend. P1 S1 S1 S1 Lc 4 DTR COM1 5 Signal Ground 6 DSR. g. And now even Col Extrusion M302 P1 is generating errors. Only users with topic management privileges can see it. It's deadly accurate and offers a 3 shot kill at the cost of effectiveness at closer ranges. M302 P1 ; disable cold extrusion checking And yes each extruder is a tool T0 G1 E20 ; move current extruder 20mm T1 G1 E20 T2 G1 E20 Edited 2 time(s). So are you still getting phase errors, or is that resolved? @jfavre said in Extruder motor not working. Without inserting the wire I tried to make a print and the extruder works. Click to Enlarge. Your config files updated for bugfix Configuration. 06. La commande G-code M302 P1 permet l'extrusion a froid. They should be about 100mm apart. M570 S180 ; allow it 180 seconds before gving a heating warning and test hotends wont be tuned. Ralms @fcwilt 8 Aug 2020, 08:57. However, Slic3r inserts this code after the first Z-lift which is befo. M302 P0 S170. 1 OS hope it might work on it. The commands I gave it was: T0 ; just to be sure M302 P1 ; I think it wM302 P1 ; allow cold extrusion. How can I make reprap firmware print without any heater or temperature sensors? Does it have a fake heater that I can make always return 200c or something to make the firmware extrude with a cold extruder, or even wi. Set the temperature (and enable) using. Chances are you are getting a message saying either "Attempt to extrude with no tool selected" or "Tool n was not driven because its heaters were not hot enough". But when i try to run it from DWC, I get the error: M302 ; report current cold extrusion state M302 P0 ; enable cold extrusion checking M302 P1 ; disable cold extrusion checking M302 S0 ; always allow extrusion (disable checking) M302 S170 ; only allow extrusion above 170 M302 S170 P1 ; set min extrude temp to 170 but leave disabled M302 P1 M584 E3:4;M563 P0 D3:4 ; Define tool 0 (no heaters assigned);M567 P0 E1:1;M584 E3:4;M302 P1 ;COLD EXTRUSION ON; Network M550 PXTP1 ; Set machine name M540 PBE:EF:DE:AD:FE:ED ; Set MAC address M552 P0. M106 P1 S1 H1 T100 ; set fan 1 value. 2mm. This topic has been deleted. The macro folder can divided into sub directories to more easily organise your macros by type. Send T0 before you try to extrude. @deckingman Replacing the P1 with P0 in the config file was the trick! Now the retract option is available immediately when I activate the hot end heater, and when it reaches 160c, the extrude option is now available. Heater 1 fault: temperature rising too slowly: expected 2. 3. I have some fillamentum wood filament, according to the website print temperature: 170 - 185 °C, however nothing prints within this range. zip. This topic has been deleted. M569 P0 S1 ; Reverse the X motor M563 P0 D0 H1 ; Define tool 1 G10 P0 S0 R0 ; Set tool 1 operating and standby temperatures M563 P1 D1 H2 ; Define tool 2 (un-comment this for dual nozzle machines) G10 P1 X19 S0 R0 ; Set tool 2 operating and standby temperatures (un-comment this for dual nozzle machines) M92 E447:447 ; Set. And, for swapping purposes, don't forget the extruder motor/cable/port. 3 ; Filter. I need to print some PCL filament, which melts optimally at 100 C°. Last edit at 01/11/2023 01:58AM by Dust. I have preheated the nozzle to 160 and also tried to issue a M302 P1 but that does not help either. g. M302 Allow Cold Extrudes [Pnn / Snn / Rnn] No Option: Report State M302 ; Report current state Pnn Cold Extrude Allow State 0=No, 1=Yes M302 P1 ; Allow cold extrusion Snn Minimum extrusion temp M302 S120 R110 ; Allow extrusion at 120°C and Rnn Minimum retractions temp retractions at 110°C M302 P1 ; Allow cold extrusion. I used to use "Pronterface" for that. Currently the paneldue displays the thermistor readings appropriately for thermistor 1 and 2 of the Duex5, which leads me to believe that the Duex5 is wired correctly. 455513e-8@gloomyandy are these values incorrect?; Tools M563 P0 S"volcano" D0 H1 F0 ; define tool 0 G10 P0 X0 Y0 Z0 ; set tool 0 axis offsetsBusiness, Economics, and Finance. @agent0810 said in Homing advice: i was able to. Suppose they are, in fact, 105mm apart. Viko. GCode and RepRapFirmware. Direct drive: Remove your nozzle,. elvoron mr approval drawing & signature required. There is a web tool for this here which can make this easier for configuring another printer. the X motor. Just need to find settings for Slice Engineering 300c thermistor, the temp reading slightly higher than actual measured with an TC thermometer. @Phaedrux @dc42 @T3P3Tony. g. 00" standard bore "competition" gasket for cast iron or aluminum cylinder heads on 302 and 351W production blocks. Featured product areas:As well as selecting the tool with e. 00°C/sec. g ; set bed and extruder max temperatures; --- SECTION: FANS ( ) ---M106 P0 S0 I0 F4 H-1 L0. Sending M302 P1 shows green as though it accepts the command, but the extrude & retract buttons are still grayed out. 36°C/sec measured -0. To test for this, with the power off swap the E0 connector on the Duet with another one e. 5mm/sec echo "Done" M82 ; set extruder to abs mode 1 Reply Last reply Reply Quote 0M574 Y1 S1 P"!P1. 0. G1 F900 ; set the feed-rate // Starting the print with Layer 0 ;Layer count: 2. M98 Punload . : till no luck with Extrusion Control jogging buttons. 1 Reply Last reply Reply Quote 0. 7mm, the output contact is engaged @ about 0. Does the motor turn? If yes, then probably it’s not having enough power to push the filament through the nozzle. M302: Allow cold extrudes add cancelling of the command; M561: Set Identity Transform - reset the transformation from calibration; Non specific G-codes Movement. The Matrice 30 series integrates multiple high-performance sensors into a lightweight and portable body. Click to Enlarge. M584 X0. I made my own slicer for the concrete printer, but for some reason the layer change is not detected, so my "Last Layer Time" is not updated. X moves almost free, lets say as much as you can tell with the belt installed without the steppers. Last edit at 01/11/2023 01:58AM by Dust. M302 P1;G92 E0. . US is first line imaging test after clinical triage; MRI only if US is equivocal and. In that case we must change the motor direction once again M569 P3 S1 ; physical drive 3 goes forwards Change S1 to S0@gixxerfast said in BL Touch not working: Which version of RRF are you using, ver 2? I can't see that you've mentioned it. M122 shows some weird messages: Driver 0: position 38683, standstill, read errors 0, write errors 1, ifcnt 23, reads 6775, writes 6, timeouts 0, DMA errors 0 Driver 1: position 38683, standstill, read errors. M83 ; set extruder to relative mode echo "Start" G1 E60 F150 ; Extrude 60mm at 2. : Just need to find settings for Slice Engineering 300c thermistor, According to this document, you need to use the following in your M308 T100000 B4680 C6. . Compared with the other two materials, this conformal metasurface has the best ability to bend. 0. @agent0810 said in Homing advice: but then when i tried to home it sent the bed to the bottom Then we need to change the motor direction for Z like we did for the X and Y. Failure to extrude in RepRapFirmware is usually caused by either cold extrusion prevention (but you have sent M302 P1 to disable that), or not having the tool selected. 1 Reply Last reply Reply Quote 0 droftarts administrators @flyscha last edited by M302 P1 ; allow cold extrude M302 S0 R0 ; allow cold extrude;M563 P1 P3 S"filament" D1 H1 H3 F4 ; define tool 1;G10 P1 X0 Y0 Z0 ; set tool 1 axis offsets;G10 P1 R0 S0 ; set initial tool 1. Here is a handy list of g-code commands Reply Quote. Set the temperature (and. M302 ; report current cold extrusion state M302 P0 ; enable cold extrusion checking M302 P1 ; disable cold extrusion checking M302 S0 ; always allow extrusion (disable checking) M302 S170 ; only allow extrusion above 170 M302 S170 P1. 0. Other possible causes are a bad stepper motor or cable. M302 P1 ; allow cold extrusion. For coding you should add M302 P0 to your ending gcode to re-enable the safety at the end of the file. Reply Quote. I did hook it up to x axis physically and it worked. Chances are you are getting a message saying either "Attempt to extrude with no tool selected" or "Tool n was not driven because its heaters were not hot enough". My printer doesn't have extrusion but when I push it manually it extrudes just fine. La commande G-code M302 P1 permet l'extrusion a froid. 9Hz when using S4 or P4 Q50 resp. 26" ; configure active-high endstop for low end on Y via pin null M574 Z1 S1 P"!P1. Thermostatic control is turned off ; Fan for the hotend M950 F1 C"out6" L0:1000 Q50 ; create fan 1 on pin out6 and set its frequency M106 P1 S1 H1 T45 C"Hotend" ; set fan 1 value. I have to turn the power off and on to reset it. g ; set bed and extruder max temperatures; --- SECTION: FANS ( ) ---M106 P0 S0 I0 F4 H-1 L0. the ONLY command that should spin a motor before the printer homes is G28. Extrusion Control in DWC unavailable, even after M302 P1. 0:0. Large delta printer [ miscsolutions. Re: How can I move E steppers? January 11, 2023 02:36AMJust to bed the gears and drive cable in. plan view. The printer functions and works as a normal syringe printer and is compatible with the Lulzbot Cura slicer software. 3 ; Filter fan. I used M302 P1 and it worked fine when I was testing my new extruder stepper motor. I cleaned it up today, swapped the nozzle and homed it to make sure nothing seemed…This is a prettified version of the Repetier-Firmware for AVR supported GCodes and MCodes as extracted from Repetier. 12/28/2022, 7:25:14 PM M302 Cold extrusion is allowed (use M302 P0 to forbid it) 12/28/2022, 7:25:05 PM M302 P1 12/28/2022, 7:23:58 PM M302 Cold extrusion is forbidden (use M302 P1 to allow it), min. The extruder can't always move as fast s the other axes, that's why my examples to move E use a slower speed (F value). M569 P0 S1 ; Reverse the X motor M563 P0 D0 H1 ; Define tool 1 G10 P0 S0 R0 ; Set tool 1 operating and standby temperatures M563 P1 D1 H2 ; Define tool 2 (un-comment this for dual nozzle machines) G10 P1 X19 S0 R0 ; Set tool 2 operating and standby temperatures (un-comment this for dual nozzle machines) M92 E447:447 ; Set. Items 1 - 36 of 42. Still no luck with Extrusion Control jogging buttons. ; Heaters;M143 H1 S260 ; Maximum heater temperature M140 H-1 ; No bed heater;M305 P1 T100000 B4138 C0 R4700 ; Thermistor parameters for heater 1;M307 H1 A577. 1 Reply Last reply Reply Quote 0. 0. Technical Explanation 1. approved - date, name. After replacing PCB managed to get everything up and running. ) You can feed filament at 800mm/m (web interface max speed is 240mm/m), at 100mm at a time, until the filament is near the nozzle. 22. M302 P0. I use FreeBSD 13. 2 the M302 P1 command doesn't help to allow the cold extrusion anymore. 1 Reply Last reply Reply Quote 0. 4 card. . You want to leave that in case the bed or anything else still has a heater, and it wouldn't fix your problem anyway. T0, you need to either heat up that tool, or enable cold extrusion by sending M302 P1. yello3d. . and Terra makes the best looking meshes by far. (You will have to switch off the temperature control as most controllers will not move the extruder stepper unless the hot end it up to temperature) Use M302 P1 on RepRapFirmware to switch cold extrusion on (allow extrusion while cold) and M302 P0 to switch it off again. M302 P0 S170. ; pre 3. 00 and cannot get the stepper motors of the extruders to work. Hi, Bringing up my re-controlled Vivendo Troodon 400 with a 6HC and 3HC. Hi all, Can anyone help using DC42 firmware I cannot get the extruder to cold extrude even when using the M302 P[1/0] to enable or disable the prevention. The Panasoic Felios F775 conformal metasurface is shown in Figure 9c. Send G1 E100 F200 to extrude 100mm of filament. Always getting "ERROR: Preheat the Nozzle!". : Just need to find settings for Slice Engineering 300c thermistor, According to this document, you need to use the following in your M308 T100000 B4680 C6. g macro is;Autoload filament macro. . droftarts administrators @flyscha last edited by . 042". 294060 INTRODUCTION INTRODUCTION This manual contains information for post processor to create EIA/ISO program according to the machine. R"Filament out" S2 ; Step 3 > After checking you click okay and it starts reversing filament M302 P1 ; Allow cold extrusion G1 E-520 F3000 ; Unwind the filament 400mm ; Step 4 > Notify user and offer option to place new filament M291 P"Remove remaining filament, insert new filament and continue" R"Insert new filament" S2 G1 E480. On Duet 3 if I send "M302P1" from the GCode console it returns "Error: Bad command". These are commands that one may enter into the OctoPrint terminal tab. M569 P1 S0 ; physical drive 1 goes forwards using default driver timings M569 P2 S1 ; physical drive 2 goes forwards using default driver timings. Macros also allow for naming gcodes with easier to remember names. retraction temperature 90. I can't help you with fans on RADDS, but "Attempting to extrude with no tool selected" means just that. wordpress. So please send T0 and M302 P1 and then see if you can send G1 E1 F100 to make. Reply Quote. G1 E500 F300. 23". 5mm/sec echo "Done" M82 ; set extruder to abs mode 1 Reply Last reply Reply Quote 0There is one extra complication in moving the extruder. So please send T0 and M302 P1 and then see if you can send G1 E1 F100 to make. GameStop Moderna Pfizer Johnson & Johnson AstraZeneca Walgreens Best Buy Novavax SpaceX Tesla. Sending T0 initiates the heater and then faults out. Using Extruder-Motor by G-Code (after using M302 P1 to enable cold-extrusion) What catches my eyes is that the text "Heater1" etc. Both Agisoft and Pix4d do some weird color smoothing that makes the meshes much less crisp looking. @agent0810 said in Homing advice: the z is at 0 at the top, so it cant go lower right? shouldnt it home at 300 something? im having issues moveing the bed. Re: How can I move E steppers? January 11, 2023 02:36AMSolved; M302 P1 command I have a duet2 wifi that I'm working on. Trying to figure out why I can't run my extruder. 0C. M569 P0 S1 ; Reverse the X motor M563 P0 D0 H1 ; Define tool 1 G10 P0 S0 R0 ; Set tool 1 operating and standby temperatures M563 P1 D1 H2 ; Define tool 2 (un-comment this for dual nozzle machines) G10 P1 X19 S0 R0 ; Set tool 2 operating and standby temperatures (un-comment this for dual nozzle machines) M92 E447:447 ; Set. Part Type: Rear Main Seals. g. 5 (2022-11-30 19:41:16) running on Duet 3 Mini5plus WiFi (SBC mode)M302 P1 ; cold extrude: G92 × 0 Y0 Z0 ; set current position to {X = 0,Y = 0,Z = 0} G92 E0 ;zero the extruded length: G1 F200 E0. J'y connais pas grand chose dans les imprimantes 3D, moi jusque là, ça fonctionnais donc je ne m’intéressai pas trop au reste, mais là, je suis bien obligé, et donc je ne sais pas faire la commande G-code que tu m'indique, ou faire ça dans Repetier-Host ?We are using two different kinds of motors, but for the Z and E we are using we are using Nema 23 bipolar 2. "M302 P1" tells the firmware it's ok to extrude though the hotend is cold. M302 works fine in a starting script or sent via console. GameStop Moderna Pfizer Johnson & Johnson AstraZeneca Walgreens Best Buy Novavax SpaceX Tesla. @agent0810 said in Homing advice: the z is at 0 at the top, so it cant go lower right? shouldnt it home at 300 something? im having issues moveing the bed. Features solid metallic core with. I am at a loss for next step. M302 P1 (This will revert the next time you reset or power off the Duet, or you can send ‘M302 P0’. M569 P1 S1 D3 V0 ; Drive 1 goes forwards, CoreXY_2, stealth chop, disable spread cycle M569 P2 S1 D3 V0 ; Drive 2 goes forwards, Z Motor, stealth chop, disable spread cycle. g ; go to purge bucket. I drive them with: M906 X1000 Y1000 Z1000 E900 I30 One of the steppers starts skipping since some days and I'm unable to find the reason. This will hopefully make it a bit easier for me to. With steps/mm so low you will get nothing like enough torque out of your motor to extrude anything, unless it is a really huge motor. For example you can create a Macro for "Allow Cold Extrude" to call M302 P1. For firmware versions 1. Fan1 configured in thermostatic mode by default. I have a Voron v0 (CoreXY) with LDO 14HS20-1504S for X and Y. Duet Web Control makes it easy to upload, edit and create new macros. 00 B0 M665 H100 TO. Tried M302 P1 four times. Failure to extrude in RepRapFirmware is usually caused by either cold extrusion prevention (but you have sent M302 P1 to disable that), or not having the tool selected. So please send T0 and M302 P1 and then see if you can send G1 E1 F100 to make. wordpress. Heating Bed manually by G-Code. Using Extruder-Motor by G-Code (after using M302 P1 to enable cold-extrusion) What catches my eyes is that the text "Heater1" etc. Not sure what could be wrong in your case as M302 with no parameters should report the current cold extrusion protection settings. Heater 1 fault: temperature rising too slowly: expected 2. After replacing PCB managed to get everything up and running. If calibrating cold, run M302 P1 (allows cold extrusion) If calibrating hot, heat your hotend to printing temp. 00°C/sec. The problem is that the G1 code runs only once, no matter what I put after the L. GameStop Moderna Pfizer Johnson & Johnson AstraZeneca Walgreens Best Buy Novavax SpaceX Tesla. Business, Economics, and Finance. . after turning off cold hotend detection with M302 P1. Slic3r 1. 155 5. g. M569 P0 S1 ; Reverse the X motor M563 P0 D0 H1 ; Define tool 1 G10 P0 S0 R0 ; Set tool 1 operating and standby temperatures M563 P1 D1 H2 ; Define tool 2 (un-comment this for dual nozzle machines) G10 P1 X19 S0 R0 ; Set tool 2 operating and standby temperatures (un-comment this for dual nozzle machines) M92 E447:447 ; Set. . Upon installation, you can see a new Revo directory in the Macros list which contains the following items:. Last edit at 01/11/2023 01:58AM by Dust.